Home

When you need accommodation anywhere around the globe, Extraspace have a range of buildings that are ideally suited for:

  • Disaster relief
  • Emergency shelters
  • Transit camps
  • Classrooms and offices
  • Living accommodation
  • Construction sites
  • Check points
  • Observation posts
  • Telco (GSM) buildings

We operate in a diverse variety of locations; from the jungles of South America to military camps in the Falkland Islands.

Understanding our clients' needs and matching those to the building solution that they require is our speciality.

Climatic and Operational conditions around the World are often under estimated by many portable building companies, however Extraspace have years of experience in operating in some of the most inhospitable locations in the World. We endeavour to fully understand our customers requirements, so that they are completely satisfied with the finished product.

Talk to us first. You will not be disappointed.

Rapidcom

The Rapidcom system is a lightweight structure designed for fast deployment at a low cost.

Available in flat packed or ready-built options.

Suitable for any purpose.

Specifications

Panels

Outer surfaces are electrostatic powder painted and cold shaped, trapezoidal sectioned galvanized steel sheets in 0.73 mm thickness. Inner surfaces are 8 mm melaminated chipboard and polyurethane based painted cementboard for living and wet areas respectively, with glasswool isolation. To connect outer surface to inner surface, there are profiles made of 2 mm electrostatic powder painted steel.

Roof

Top surface made of .53 mm thickness unpainted trapezoidal sectioned galvanized steel sheets and inner surface made of 8 mm melaminated chipboard or cementboard painted with PVA base paint depending on the used area are supported with statically suitable steel frame isolated with glasswool.

Chassis

18 mm chipboard or cementboard is fixed onto the steel frame of which bottom side is covered with 0,53 mm unpainted trapezoidal sectioned galvanized steel sheets. Isolation material is generaly polystrene foam.

Transcom

Transcom is a robust accommodation system that can be stacked 3-high.

It is fully modular and can be fitted out with kitchens and sanitary equipment as required.

See also TransPAK.

Specifications

Panels

Outer surfaces are electrostatic powder painted and cold shaped, trapezoidal sectioned galvanized steel sheets in 0.73 mm thickness supported with galvanized and/or painted steel structure. Inner surfaces are 8 mm melaminated chipboard and polyurethane based painted cementboard for living and wet areas respectively, with glasswool isolation.

Roof

Top surface made of .53 mm thickness unpainted trapezoidal sectioned galvanized steel sheets and inner surface made of 8 mm melaminated chipboard or cementboard painted with PVA base paint depending on the used area are supported with statically suitable steel frame isolated with glasswool.

Chassis

18 mm chipboard or cementboard is fixed onto the steel frame of which bottom side is covered with 0,53 mm unpainted trapezoidal sectioned steel sheets. Isolation material is generally polystyrene foam.

Telecommunications Shelters (GSM)

Available with box profile or flat steel cladding, our GSM shelters can be fully fitted out with:

  • Air conditioning
  • DC fan
  • AC distribution board
  • Power meter box
  • Internal cable trays
  • Heat & smoke detectors
  • Door mat and folder table
  • Ice shield
  • Panic door latch
  • Generator power access
  • Fire extinguisher

Specifications

Panels

Outer surfaces are electrostatic powder painted and cold shaped, Trapezoidal sectioned galvanized steel sheets in 0.73 mm thickness supported with galvanized and/or painted steel structure having enough capacity for side load carriage. Inner surfaces are 8 mm melaminated chipboard. 

Roof

Top surface made of 0.53 mm thickness unpainted trapezoidal sectioned galvanized steel sheets and inner surface made of 8 mm melaminated chipboard are supported with statically suitable steel frame designed according to the requested specifications isolated with glasswool.

Chassis

18 mm chipboard is fixed onto the steel frame of which bottom side is covered with 0,53 mm unpainted trapezoidal sectioned steel sheets. Chassis frame design is based on the user specifications. Polystyrene foam is the isolation material used inside the chassis.

Campcom

This panellized building system is ideal for large transit/labour camps, food halls, offices and dormitories.

Specifications

Panels

Outside: Outer surfaces are electrostatic powder painted and cold shaped, trapezoidal sectioned galvanized steel sheets in 0.73 mm thickness supported with galvanized and/or painted steel structure. Inner surfaces are 8 mm melaminated chipboard and polyurethane based painted cementboard for living and wet areas respectively, with glasswool isolation.

Inside: Both surfaces are 8 mm chipboard or PVA base painted cementboard with glasswool isolation.

Roof

Top surface made of .53 mm thickness unpainted trapezoidal sectioned galvanized steel sheets lays on the steel roofing system made of steel trusses and purlins with the connection profiles of suspended ceiling.

Ceiling

Suspended ceiling is made of electrostatic powder painted galvanized steel lamelling system in 0,73 mm thickness having the depth of 27 mm. Isolation material is glasswool laid between roof cladding and suspended ceiling.

Blast Resistant Offices

Blast Resistant Portable Accommodation where design approval for the structure of the unit has been designed and manufactured to meet the blast resistance criteria under the following conditions:

  • Walls - Reflected overpressure of 650 mbar for a positive phase duration on 100msec
  • Roof – The roof for the 650mbar module (reflected on the front face) would need to be able to resist the 320mbar pressure (side on or overpressure) for the duration of 100msec
  • Floor– Reflected overpressure of 650mbar for a positive phase duration of 100msec
  • Windows - Reflected overpressure of 650mbar for a positive phase duration of 100msec
  • Door - Reflected overpressure of 650mbar for a positive phase duration of 100msec
  • Door has been classified as Category 1

All Blast loadings assumed to be of a shock wave form i.e instantaneously rising at time t=0 to the maximum overpressure and decaying linearly to zero mbar at t=100msec.

  • Petrochemical Industry Recommended Practice on Design of Blast Resistant Buildings. Final report (April 1998) Appendix 1
  • Petrochemical Industry Recommended Practice on Design of Blast Resistant Buildings. Commentary (April 1998) Appendix 2

All relevant design calculations are held within Eldapoint Ltd Quality and Contract records.

Units can be manufactured any size up to 32ft x 10ft. Designs for lower specifications are also available.

Specifications for Blast Resistant Office 23ft x 100ft (2008)

Walls

Manufactured from 3.0mm mild steel folded to form side panels welded to base and roof. Timber studding 75mm x 45mm CLS fully insulated with 100mm Rockwool and lined with Cotton EXL vinyl on ply

Roof

Manufactured from 3 corry profiled 2.0mm mild steel , welded in place. Timber studding 75mm x 45mm CLS fully insulated with 100mm Rockwool and lined with Cotton EXL vinyl on ply

Floor

Manufactured from 150mm x 75mm PFC rails with 100mm x 50mm RHS bearers c/w 2no 50mm x 50mm SHS longitudinal rails. steel under-drawn Floor is from 18mm Far Eastern Plywood Floor finished in 1.5mm black Polyflor XL heat welded at seams. Fork pockets are incorporated in the design of the floor (1800mm centres)

Windows

15mm fixed pane laminate designed to withstand upto 650 mbar reflected overpressure

Doors

Steel door designed to withstand upto 650 mbar reflected overpressure

Lifting

All units are fitted with 4no lifting points at corners and 4 extra lifting points are welded to top rail at specified point. Heavy duty Stackable Jack - legs are also fitted at 5486mm x 3075mm centres. Outer leg manufactured from 70mm x 70mm RHS, Inner leg manufactured from 60mm x 60mm RHS legs to have 16mm 50D grade round for pin and an strengthener plate around hole,

Finish

All units finished colour to be BS4800 ( Manor coatings compliant paint 630c).

Fire Rated Buildings

If you need a Fire Rated Building (fully certificated) then the The Phoenix Range of Fire Rated Buildings can meet your needs.

Fire Rated Buildings can be manufactured with a choice of flat sided or corrugated steel side walls and all windows have a neat and tidy fire curtain installed that will automatically drop in the event of a fire, thus preventing fire spreading from the windows.

The Phoenix Range of Fire Rated Buildings covers all unit sizes from 16ft x 10ft up to and including 32ft x 10ft.

Electrical & Plumbing fit: electrics to IEE 17th Edition with all distribution boards with MCB's and RCD. All Gas fitting CORGI approved.

Locking systems: all accommodation units have High Security Multi-Locking System doors as standard.

Specifications for Fire Rated Steel Offices

Walls

Manufactured from 16-gauge steel to BS1449 Part 1 1983 HR4 Drawing quality, folded to form side panels welded to base and roof. External and internal joints sealed using fire proof sealant Timber studding 75mm x 45mm CLS fully insulated with 50mm RWA50 Rockwool to give a and lined with plasterboard covered with vinyl.

Roof

Manufactured from 3 corry profiled 16-gauge mild steel to BS 1449 Part 11983 HR4 Drawing quality, welded in place. Interior roof manufactured from 16g mild steel , insulated with 50mm RWA45 Rockwool and covered with 6mm plasterboard to act as thermal break. A decorative finish is applied on the inside.

Floor

Manufactured from 100mm x 50mm RSC rails with 50mm x 50mm RHS bearers. Floor is from 18mm Far Eastern Plywood Floor is fitted over a steel sheet then finished in 1.5mm Polyflor XL heat welded at seams. Fork pockets are incorporated in the design of the

Windows

Georgian wired sliding aluminium framed windows to be fitted, standard window size to be 914mm x 914mm. An internal fire curtain is fitted to automatically drop in event of a fire.

Shutters

4no new style Kirncroft Ltd shutters internally operated.

Doors

1no steel door is fitted .Door closer to be fitted as standard. An angle is welded all round door frame for linking purposes; also a staircase bracket is also welded below.

Lifting

All units are fitted with 4no lifting points at corners and 4 extra lifting points are welded to top rail at specified point. Heavy duty Jack - legs are also fitted. Outer leg manufactured from 70mm x 70mm RHS, Inner leg manufactured from 60mm x 60mm RHS legs to have 16mm 50D grade round for pin and an strengthener plate around hole.

Electrics

Installation consists of PVC insulated and sheathed twin and earth in surface mounted trunking. All trunking to be new design (Falcon) size EM4 around top and MC2 coming down for sockets etc (all joints to be capped). Overcurrent and fault current protection is afforded by a residual current device controlled consumer unit fitted with miniature circuit breakers. Installation to comply with current IEE regulations.

Expanda